Flexible Multilayer Busbars
Press-Welded Shunts are flexible multilayer busbars for high-current industrial environments and power distributions. Made from stacked ultra-thin copper strips, their contact zones are press-welded into a solid piece of copper. This design effectively absorbs severe mechanical vibrations and massive thermal expansion. The strips are available in three variants:
- Cu-OF (CW008A)
- Cu-HCP (High Conductivity, Phosphorus deoxidised CW020A)
- Cu-DHP (Phosphorus deoxidised, High Conductivity, CW021A)
Press-welded Terminals
The press-welding process physically fuses the individual strips into a single solid piece of copper, thereby completely eliminating the internal contact resistance between the strips. In addition, this solid end piece ensures a clean surface finish, preventing cracks or “tearing” during drilling, punching, or the machining of custom screw patterns.
Finally, to optimize long-term performance and counteract oxidation, the connection surfaces can undergo a special surface treatment in which they are electroplated using a precise, locally limited surface coating.
Specifications Press-welded Shunts
| Technical Parameter | Standard Manufacturing Range | Customized Options (On Request) |
|---|---|---|
| Shunts Geometric Formats | Flat, straight rectangular expansion connectors | Pre-bent shapes (L-shape, S-shape, V-shape), multi-branch shunts, or complex 3D-formed profiles |
| Shunts Mechanical Flexibility | High single-axis flexibility (ideal for linear expansions and absorbing transformer/generator vibrations) | Multi-axial flexibility via pre-formed foil loops, or variable flexibility with mixed-thickness laminate stacks |
| Shunts Cross-Sections [mm²] | 50 to 1200 | Extra-large heavy industrial cross-sections up to 3000 mm² or parallel multi-shunt block assemblies |
| Individual Strip Thickness | 0.10 and 0.20 mm copper strips (industry standards for optimal atomic diffusion) | Ultra-thin 0.05 mm strips (for extreme micro-vibrations) or 0.30 mm strips for higher structural rigidity |
| Terminals | Pure molecular press-welding (high-pressure diffusion welding forming a solid, uniform copper contact block) | Additive brazing, electron-beam welding, or the integration of solid copper clad plates onto the contact pads before welding |
| Terminal Finishes | Bare welded copper contact surfaces | Tin-plating / Silver-plating / Nickel-plating contact zones to prevent oxidation in severe environments |
| Terminals Geometric Formats | Flat rectangular solid pads with standard drilling or inline multi-hole punching | Custom hole patterns (DIN/NEMA standards), cross-slotted holes, integrated threaded inserts, or CNC-machined contact profiles |
| Geometric Profile Style | Primary Application & Movement |
|---|---|
| Straight Shunt (Standard flat profile) | Expansion & Vibration: Absorption of linear expansion and micro-vibrations in straight-line busbar connections. |
| V-Shape - Single Loop (Pre-bent expansion arc) | High Axial Displacement: Engineered for thermal contraction and expansion loops. |
| S-Shape - Offset Profile (Dual-bend step bridge) | Level Compensation: Connects parallel busbars located on different structural planes or steps and for heavy thermal expansion |
| U-Shape - Deep Loop (Maximum flexibility arch) | Multi-Directional Movement: Deep expansion loop for heavy vertical and horizontal dynamic shaking. |
| Straight with Rigid Backing (Reinforced solid terminal block) | Heavy Hardware Mounting: Flat shunt with integrated solid block reinforcement for high-torque bolting. |
| L-Shape - 90° Angle (Right-angle corner profile) | 90-Degree Redirection: Connects orthogonal phase bars inside compact switchgear housings. |
| Twisted Shunt - 90° Axial Twist (Phase rotation profile) | Orientation Realignment: Connects horizontal busbars directly to vertical switchgear or breaker terminals. |
| C-Shape / Rolled-up Loop (Circular expansion cylinder) | Extreme Axial Compression: Maximizes structural compression travel distance in extremely tight spaces. |
| Multi-Branch / Comb Shunt (Interleaved parallel stacks) | Ultra-High Current (Ampacity): Multi-layered branch configuration for high-kilowatt power distribution. |
The data are based on one connection working in a stabilized room temperature. The shunt is vertically installed and cooled by natural convection. The open space around the shunt is equal or more important than the width of the shunt.
The diagram enables the selection of the press welded shunts according to the different parameters Current (Amps) requested, Room temperatures of 25°C, 35°C or 45°C, and the width of the shunt.









Advantages of Press-Welded Shunts
Physical Integrity
- Solid Terminals without compromising material properties
- 100% retention of original electrical and thermal conductivity
- Retention of the original mechanical properties of the flexible copper strips
Excellent vibration damping
- Highly flexible center sections, designed for strong mechanical vibrations
- Seamless compensation for significant thermal expansion and contraction
- More reliable and durable than rigid copper busbars or strands
Controlled welding cycle
- Strict limitation of temperature spikes during molecular fusion
- Complete prevention of raw material oxidation
- Reliable protection of critical flexible transition areas
No chemical residues
- Special low-temperature press welding (BT) for silver-plated strips
- 100% flux-free joining process
- Eliminates the risk of corrosive chemical residues being trapped inside the laminates
Material Specifications Press-welded Shunts
| Parameter | Technical Specification |
|---|---|
| Copper Classification | EN 13599 (Copper plate, sheet, and strip for electrical purposes) |
| Designation | Cu-OF (Oxygen Free CW008A), Cu-HCP (High Conductivity, Phosphorus deoxidised CW020A) & Cu-DHP (Phosphorus deoxidised, High Conductivity, CW021A) |
| Minimum Copper Content | ≥99.95% |
| Max. Electrical Resistivity at 20°C (Annealed Temper) | ≤0.01724 Ω⋅mm²/m (Equivalent to an electrical conductivity of ≥58 MS/m or 100% IACS) |
| Mechanical Resistance Laminates | Manufactured from ultra-thin, fully soft-annealed individual strips |
| Tensile Strength (Rm) | 200−250 N/mm² |
| Performance | Engineered for maximum elastic expansion and long-term structural fatigue life |
| Hardness | <65 HV |
| Shunts Coating Type | Standard Coating Thickness | Optimal Operating Conditions & Environments |
|---|---|---|
| Bare Copper (Standard) | N/A | Controlled industrial environments. Best suited for clean, dry indoor installations such as standard low-voltage switchgear cabinets and transformer enclosures. Max continuous temp: Up to 150°C. |
| Tin-Plating (Sn) (Corrosion Protection) | 5.0 µm to 10.0 µm (Thicker layer optimized for solid contact blocks) | Humid and coastal environments. Essential for preventing copper oxidation in damp conditions. Crucial as a sacrificial interface layer to prevent galvanic corrosion when bolting the copper shunt directly to aluminum busbars. Max continuous temp: Up to 150°C. |
| Silver-Plating (Ag) (High-Performance) | 5.0 µm to 10.0 µm | High-power transmission & low-loss grids. Provides the absolute lowest contact resistance at the joint interface. Ideal for medium-to-high voltage power distribution, generator connections, and applications where micro-volt drops must be avoided. Max continuous temp: Up to 200°C. |
| Nickel-Plating (Ni) (Extreme Environments) | 3.0 µm to 10.0 µm | High-heat and chemically aggressive zones. Recommended for heavy industrial applications such as chemical processing plants, foundries, or furnace connections where the shunt is exposed to ambient heat and corrosive gases. Max continuous temp: Up to 260°C. |
| Parameter | Standard / Value |
|---|---|
| Copper Classification | High-purity oxygen free copper grade : Cu-OF (CW008A), Cu-HCP (High Conductivity, Phosphorus deoxidised CW020A) & Cu-DHP (Phosphorus deoxidised, High Conductivity, CW021A) |
| Designation | EN 13599 (Copper plate, sheet, and strip for electrical purposes) |
| Minimum Copper Content | 99.95% pure copper |
| Copper Condition | The terminal end area is completely solid and rigid due to atomic bonding (no solder or filler metal used). Metallurgical structures are completely unified, ensuring zero degradation in electrical conductivity. |
| Terminal end Thickness | 5 to 20 mm (Standard range). Thickness matches to the stack of the compressed copper strip, or is custom-machined/calibrated to align perfectly with standard switchgear and transformer busbar layouts. |
| Surface Options | Bare Copper (Standard), Tin-plating, Silver-plating, Nickel-plating |
IWE Certificates
Uncompromising quality, backed by global certifications. International Wire Europe is certified to DIN EN ISO 9001:2015.
Contact & Locations
We are a global network of local experts who are here to support you. Contact us today to move your project forward.
Request a quote
IWE provides custom-made braids and busbars to unlock your system's full potential. Request a quote today.
Applications of Shunts
Press-welded Shunts deliver reliable, continuous current transfer across demanding high-voltage and heavy industrial power systems:
Power Generation & Heavy Industry: High-capacity busbars for electric arc furnaces, chemical electrolysis plants, and grid transformer stations.
Transformers & Grid Infrastructure: Vibration-resistant busbars that compensate for thermal expansion cycles between power transformers and distribution busbars.
Renewable Energy: Rugged, weather-resistant power connections and grounding shunts engineered for onshore and offshore wind turbines.
Engineering Support
Do your installations require complex 3D bending shapes, specialized multi-hole drill setups, extra-flexible shunts with mechanical reinforcements, or added heavy contact plates?
Our expert design teams assist you from prototype through to full serial manufacturing.